Copd Nebulizer Should Copd Patient Have An Oxygen Tester, What Levels Should Oxygen Be Started? What Is A Safe Oxygen Level?

Should copd patient have an oxygen tester, what levels should oxygen be started? What is a safe oxygen level? - copd nebulizer

I'm sorry to ask 3 questions, but only 5 points. Friends who suffer from COPD. The proportion of oxygen, 95-97. He is now 90th Nebuliser at home was told he could use it at night. I am afraid that this is a dangerous level, can be treated. My mother has the disease in their specialists, the opposite of oxygen started the first 10 years. Later started nebulizer. Everyone is different and this may be the protocol to have been there.

5 comments:

retired_... said...

at a rate of 91% on room air oxygen via nasal cannula or mask should not start the beginning of the rebreather flow to 1 or 2, including the electrical lines can still be much higher if the lungs react maintaining levels of carbon dioxide not oxygen levels . If you have a smart meter O2 saturation

retired_... said...

at a rate of 91% on room air oxygen via nasal cannula or mask should not start the beginning of the rebreather flow to 1 or 2, including the electrical lines can still be much higher if the lungs react maintaining levels of carbon dioxide not oxygen levels . If you have a smart meter O2 saturation

Katetrin... said...

I was told to stop all medication and let nature take its course. At this moment I can not speak. I gotta go call 911th

911 was occupied, so I try to talk for a minute. Caution, it's an ambulance on the street. I'll try to catch a ride to ...... Hopefully, your friend is better .....

pulmonar... said...

You have to be very safe if you place a COPD patient on oxygen due to the fact that the unity of inspiration in hypoxia. It is for patients with COPD who have less O2 SATS normal. because they retain carbon dioxide. A 90 02 SA is not bad for a patient with COPD, when it falls to a lower nasal cannula, may be feasible. But it requires a low flow resistance. If your SA is controlled by an O2 pulse ox, blood gases may take place because the SpO2 (pulse-OX) is not 100% correct. SpO2 is an estimate of the state of oxygen supply. Readings below 90 to a pulse ox will not be accurate

atreadia said...

A hand-held personal device SpO2 (oxygen control) is a good investment for people with severe COPD, or emphysema.

An oxygen content of 88% on room air if oxygen is to a person, the oxygen levels be maintained above 92% to be made available.

The reccommendation by the doctor of your friend is probably a good idea. Most people with COPD receive scripts for nebulizer treatments 3-4 times per day for the purpose in view.